Description
AS2702 (SAP4.1) is a new generation AS-Interface slave device,
which supports AS-Interface bus systems with up to 62 slave
modules.
Each slave module is equipped with an AS2702 device, which
interfaces the module to the unshielded 2-wire ASInterface
bus for serial bidirectional data communication and power
extraction.
Data communication over the AS-Interface takes place in master
slave fashion, which foresees that all slave devices AS2702
connected to the bus are sequentially and cyclicly addressed
by a single, central master unit. Data on the ASInterface
bus are Manchester encoded and can be found as sin2-pulses
with a Vpp of between 3V and 8V on top of the bus’ dc
voltage of nominally 30V.
AS2702 regulates the nominal dc bus voltage of 30V internally
down to 5V to supply it’s internal circuitry including
a 16 x 8 bits EEPROM, as well as down to a nominal supply
level 24V with a max. loading of 35mA for the actuators and
sensors connected to it at the field side.
Each slave device AS2702 may interface to up to 4 sensors
or 3 actuators. An AS-Interface bus system based on AS2702
may hence link as many as 248 sensors and 186 actuators to
a single master unit.
Slave device AS2702 (SAP4.1) is system compatible with predecessor
device AS2701A (ISA3+): slave modules equipped with AS2702
(SAP4.1) will run in existing AS-Interface bus systems based
on AS2701A (ISA3+).
The AS-Interface concept is well established as a standardized
digital bus system for industrial automation.
|